Industrial facilities and manufacturing plants have hazardous locations in which hazardous and explosive gases could be present. Explosion-proof enclosures are used by such facilities to ensure the safe housing of electrical components that could cause a spark and ignite these gases in the atmosphere.
If you want to learn more, please visit our website MAM.
They are a cast aluminum or iron box that can withstand a heavy-duty explosion from gas entering the box and igniting, and then containing the explosion. These boxes are designed in such a way that they can significantly reduce the risk of the flame getting outside of the box and igniting the atmosphere where flammable vapor, gases and dust particles are present. Places like oil refineries, feed mills, chemical plants, plastic plants and fireworks factories are a few such industrial facilities that employ explosion-proof enclosures. Their primary purpose is to protect industrial equipment and devices against internal explosions.
If your industrial facility is located in an area that has been designated as hazardous according to the standards of the National Fire Protection Association (NFPA) and if your facility is utilizing electrical components like circuit breakers and switches, you need to use certified explosion-proof enclosures. Why is doing so important? Remember that the success and productivity of any industrial facility depends on how much importance it gives to safety. Hence, by using explosion-proof enclosures, your plant will comply with the regulations of the Occupational Safety and Health Agency (OSHA), the location classifications outlined by the National Electric Code (NEC) and the specifications crafted by the National Electrical Manufacturers Association (NEMA). Using Non-Explosion Proof standard electrical enclosures in a hazardous area is comparable to a hand grenade. Flammable gases can fill up in the enclosure and when a spark occurs from one of the devices inside it will cause an explosion throwing shrapnel metal, electrical components and igniting the atmosphere causing a chain reaction explosion in the facility.
A major advantage of using explosion-proof enclosures, or “IS” cabinets by Spike Electric, is that they prevent an internal explosion or inferno from spreading to the surrounding area. Ultimately, these explosion-proof enclosures ensure the safety of the facility and more importantly the personnel working in it. Using these safe and effective enclosures will help in preventing property damage and will ensure that you, your manufacturers and investors don’t have to endure heavy financial damage in the event of an explosion.
What does it take to make an effective explosion-proof junction box or cabinet? An incredible mechanical engineering design is what you need. Design for such enclosures and storage boxes differ with each manufacturer. Since the requirements of every industrial facility and the intensity of hazardous locations vary, different strategies are adopted to develop the design for these enclosures and storage boxes. Below are some common techniques that are used for explosion-proofing that we have curated for you.
NEC, CEC and CSA: • Class I, Division 1 & 2, Groups B, C, D • Class II, Division 1 & 2, Groups E, F, G • Class III • UL Standard • cUL to CSA C22.2 No. 30, No. 25 • NEMA Type 3, 3R, 4, 7BCD, 9EFG • Enclosure Type 4X
European IECEx: • Ex db IIB+H2 Gb • Ex tb III C Db IP66 • -20°C ≤ Ta ≤ +60°C • IECEx ETL 13.U
European ATEX: • II 2 G D Ex db IIB+H2 Gb • Ex tb IIIC Db IP66 • -20°C ≤ Ta ≤ +60°C • ITS13ATEXU certified
Explore Spike’s ECP Series or our EJB Series enclosures.
Who should be adopting flameproofing? Industrial facilities that operate in environments with high-pressure systems should adopt flame-proofing for the design of safety cabinets and enclosures. With the help of the flame-proofing technique, if there is an internal spark or an internal ignition within the framework of a device, the proofed enclosure will control the impact of the resulting explosion. In flame-proofing, strong and firm materials like cast metal and fabricated steel are employed to build the outer shell of the storage cabinet. With flame-proofing, you can ensure the control of any excess pressure resulting from an internal eruption. This will ultimately prevent the spread of the fire to the immediate surroundings of the enclosure.
Ingress protection is a process that involves the protection of electrical enclosures to prevent the entry of vapor, dust and other foreign particles in an electrical enclosure. In environments where water or dust could damage electronic components, a sealed enclosure is used to prevent such ingress and safe house the electrical equipment.
Explosive gas or vapor mixture that accumulates within an Explosion Proof cabinet tends to give rise to dangerously high pressure. As a result, the electrical components will become heated beyond the safe limit and can potentially give rise to ignition or sparking. Purging involves a segregation method that supplies a protective non-explosive gas into the enclosure like nitrogen. Pressurizing also hinders the entry of dust that may be potentially combustible into the metallic box. Standard Non-Nema 7/9 cast enclosures would not be used in this application. A minimum of Nema 4 gasketed enclosure rating is suggested for a purged electrical cabinet. For larger cabinets this maybe the more cost-effective route rather than a large bolted Nema 7 enclosure.
Check out one of Spike’s purge pressurization units.
Want more information on explosion proof control panel? Feel free to contact us.
What does encapsulation involve? The explosion-proof enclosure or cabinet is filled with a resin that provides significant resistance to particular environmental conditions. During the process of encapsulation, the resin isolates the electrical components that may potentially lead to sparking, heating, and the ignition of explosive gases, vapors or other dust and fine particles.
The primary distinction between an Explosion Proof Enclosure and an Intrinsically Safe (IS) enclosure is that the former follows a strategy involving containment whereas the latter is about offering prevention. To state simply, IS enclosures eliminate the risk of ignition or explosion by following a prevention technique, unlike explosion-proof enclosures that offer protection after the problem has occurred.
The design of IS enclosures ensures the safety of the electrical framework of a component. The primary purpose of these enclosures is to minimize the values of current, voltage, and temperature of the circuit of a device while it is operating.
An intrinsically safe junction box or cabinet provides notable resistance to overheating. Hence, this enclosure is suitable for use in industrial facilities that function in high-temperature environments. The circuitry of an IS enclosure does not produce sparks or electric discharges which can trigger an explosive mixture of gas or vapor sense intrinsically safe components must be used.
Explore Spike’s Ex-Cell Stainless Steel and Painted Steel Enclosures.
Junction boxes are an ideal choice for industrial plants that allow rigid conduit systems to be connected and operate in potentially explosive surroundings. For example; gasoline pumps. These boxes are designed to contain electrical components and wiring that may initiate a spark or an ignition. These types of enclosures are rain-tight, heavy-duty that are explosion-proof.
They control the amount of energy transported to electrical equipment in hazardous environments. IS barriers restrict the energy supply to circuits. This helps in the prevention of the ignition of combustible substances in various systems. For example, dangerous power surges may cause the ignition of explosive gases which might spread to the surrounding environment.
Every Explosion Proof Enclosure, intrinsically safe barrier, junction box or any other containment enclosure should comply with the standards outlined by NEC Hazardous Area Classifications. The design, framework and functionality of all these enclosures should abide by the defined regulations. However, manufacturers have the liberty to comply with significant ratings by NEMA. What are the NEC specifications that you need to abide by? That completely depends on whether you intend on deploying an Intrinsically Safe Cabinet or an Explosion Proof Enclosure. Given below are a few NEMA or NEC classifications and ratings for Explosion Proof and Intrinsically Safe Enclosures that we have curated for you:
The International Electro-Technical Code (IEC) Zoning segregates or categorizes hazardous areas depending on the properties of combustible substances that they contain. This zoning process also considers the possibility of the presence of combustible gases, vapors or dust in a particular environment.
Article 505 from NEC publication outlines the classifications of similar locations. For example, consider the A Zone 1 designation. This zone refers to d-rated flame-proof enclosures that are meant to function in environments that may potentially consist of combustible measures of flammable gases while operating normally. This article also mentions e-rated cabinets hosting electrical components that do not produce electrical discharges, sparks or extremely high temperatures while operating under normal conditions.
Article 500 of the NEC allows the usage of purged or pressurized cabinets as a substitute for Explosion Proof Enclosures. When? Only under specific circumstances. Primarily, these enclosures should satisfy the requirements outlined by the NFPA 496 regulation. IEC Zone 1 and 2 also mention specifications concerning purged and pressurized storage systems.
Industrial facilities use Explosion Proof Enclosures, IS cabinet boxes or other types of pressurized purged enclosures to ensure the safety of electrical equipment and the personnel amidst various types of hazardous materials like combustible gases, vapors and dust. These industrial facilities are getting their hardware for hazardous area operations constantly updated according to intrinsically safe standards. Through this, they can successfully prevent explosions and fire accidents that might cause severe damage to personnel and equipment in the facility. Most significantly, OSHA can charge a heavy penalty on companies and industrial facilities that don’t employ IS or Explosion Proof Enclosures to strengthen the safety factor while carrying out operations in dangerous environments, notably in places of high temperature and high pressure.
Are you in search of explosion-proof enclosures for your industrial facility? Do you want to purchase an ideal enclosure for use in a hazardous environment? Step into our Spike Electric’s certified shop for enclosures and industrial explosion proof products. With plenty of expert guidance through the purchase, you will not be disappointed!
For more waterproof Lighting Fixtureinformation, please contact us. We will provide professional answers.