An electrical reactor is an inductor designed to add impedance to an electrical circuit. By limiting or shaping current, it can help reduce electrical stress, support harmonic mitigation, or control switching-related effects, depending on its design and position in the system. Common types include line reactors, load reactors, DC link reactors, and filter reactors. To select one, match its function and electrical ratings to the supply, equipment, load, and installation conditions rather than choosing by name alone.
This guide is for electrical equipment buyers, panel builders, system integrators, and engineers comparing reactor options for industrial or commercial projects. It explains the main types, how applications differ, which specifications to confirm, and what to ask a supplier. ANNEZEE works with buyers sourcing electrical equipment and can review application details to help identify a suitable reactor specification.
A reactor uses inductance to oppose changes in current. In practical systems, that impedance can reduce the rate or magnitude of certain current disturbances, subject to the reactor’s design and the circuit conditions. A reactor is not a substitute for a correctly selected protective device, and it does not automatically correct every power-quality problem. Its effect depends on where it is installed and what electrical issue the system needs to address.
Reactors may be used with motors, variable frequency drives (VFDs), power converters, capacitors, or harmonic-filter circuits. Some are connected in series with a power path, while others form part of a tuned or detuned network. A reactor’s voltage, current, frequency, impedance, insulation, and thermal ratings must suit the application. The system designer should confirm coordination with connected equipment and applicable installation requirements.
A line reactor is installed on the input side of a drive or other power-electronic equipment. It adds impedance between the supply and the equipment, which may help limit current disturbances and reduce the impact of certain line-side events. Its suitability depends on the supply characteristics, drive requirements, and the problem being addressed. Confirm whether the equipment manufacturer recommends an input reactor and what ratings it specifies.
A load reactor is typically installed between a VFD and its motor. It can help moderate the effects of the drive’s output waveform on the motor and connected cable, depending on the drive, cable length, and reactor design. It should not be assumed to provide the same protection as a dedicated output filter. Check the drive manufacturer’s guidance, motor insulation considerations, and the intended cable arrangement before choosing this option.
A DC link reactor is placed in a drive’s DC section when the equipment design provides for it. It can influence current ripple and the electrical behavior of the DC bus, but the required configuration is specific to the converter. Harmonic-filter reactors, by contrast, are selected as part of a filter network to work with other components at intended frequencies. Filter design requires system information; a standalone reactor should not be treated as a complete harmonic solution.
| Reactor type | Typical position | Selection focus |
|---|---|---|
| Line reactor | Supply side of a drive or converter | Supply voltage, load current, drive guidance, and system conditions |
| Load reactor | Between drive output and motor | Drive output, motor, cable length, and installation arrangement |
| DC link reactor | Converter DC section | Converter design and required DC-side electrical ratings |
| Filter reactor | Within a filter circuit | Filter design, system frequency, and companion components |
In a motor-drive installation, first establish whether the concern is on the incoming supply side or the drive-to-motor side. A line reactor and a load reactor occupy different positions and address different circuit conditions, so they are not interchangeable by default. For a converter cabinet, confirm whether the reactor is specified as an external component or is already included in the equipment. For a harmonic concern, gather system measurements or engineering analysis before selecting a filter reactor.
Electrical systems operate at different supply frequencies, commonly 50 Hz or 60 Hz, and the reactor must be suitable for the intended frequency. As an illustration of the information needed for a quotation, a buyer might describe a 400 V, 50 Hz supply and a 100 A load; these figures are an example only, not a recommended reactor size. Actual selection also depends on the connection, operating profile, allowable temperature rise, enclosure, and other design constraints. Use the equipment nameplate and project documentation rather than estimating critical values.
Link to ANNEZEE
Write down the issue the reactor is intended to address, such as input-side current disturbance, drive output effects, or inclusion in a filter circuit. Identify its proposed location on a single-line diagram or equipment schematic. This prevents a common sourcing error: requesting a reactor without distinguishing its function. If the root cause is uncertain, involve the system designer or a qualified power-quality specialist.
Provide rated voltage, continuous current, frequency, phase configuration, inductance or impedance requirement, and any relevant overload conditions. Clarify whether a stated current is the reactor’s continuous operating current or a peak, starting, or short-time value. For drive applications, share the drive model and motor data where available. The supplier should confirm that the proposed specification is compatible with the connected equipment, not just one matching nameplate figure.
Check mounting method, available space, ventilation, ambient conditions, connection terminals, and enclosure requirements. Reactor losses generate heat, so installation clearances and cooling conditions can affect operation and service life. Confirm the insulation and temperature ratings required by the project. Installation, protection, and commissioning should follow the equipment documentation and be handled by qualified personnel.
For a filter application, ensure the reactor is specified as part of the complete circuit, including compatible capacitors and any damping or protection components. For drive applications, confirm cable length limits and any output-filter requirements with the drive supplier. Ask for the relevant product datasheet and dimensional information before approval. Where system behavior is uncertain, request engineering review rather than relying on a generic selection rule.
Reactor pricing varies with electrical ratings, construction, materials, customization, and order quantity. A standard configuration may be quoted differently from a design requiring special terminals, enclosure, or mounting dimensions. Minimum order quantity and production lead time also depend on the selected configuration and current manufacturing schedule. Buyers should request these details in a written quotation instead of assuming that all reactor types share the same commercial terms.
To make a quotation more accurate, submit the application, electrical ratings, annual or project quantity, destination, required delivery date, and any drawings or interface requirements. Ask the supplier to identify assumptions and deviations in the offer. Compare quotations on equivalent ratings, scope, documentation, and delivery terms. A lower initial price may not represent the best fit if the specifications or included services differ.
These questions help buyers compare suppliers on technical clarity as well as commercial terms. Request evidence for any claimed compliance or performance characteristic that is important to the project. Do not infer certification, test results, or compatibility from a product description alone. Record agreed specifications in the purchase documentation to reduce avoidable ambiguity.
An electrical reactor adds inductance to a circuit, but the right type depends on its location and purpose. Line reactors, load reactors, DC link reactors, and filter reactors serve different roles, so selection begins by defining the system issue and connection point. Voltage, current, frequency, impedance, thermal conditions, and connected equipment all need review before purchase. A reactor should be treated as part of an engineered electrical system, not as a universal solution for power-quality or drive problems.
For your next step, prepare the equipment details, application description, required quantity, installation constraints, and target delivery date. ANNEZEE can review these inputs and discuss reactor supply options for your project. Contact our team with a schematic or specification when available so we can clarify requirements and prepare a more relevant quotation.